Products

Magic Effects Interface

This DMX interface is used to easily control effect devices with a DMX-512 input with a PFE Advanced receiver and to integrate these devices in the system. Typical applications are the control of smoke machines and flame projectors.

It is required that the receiver is equipped with the Terminal function. This enables the user to program several firing cues to each output and to determine the duration how long the outputs should be active.

The interface comes with a safety input and five control inputs and is powered from the receiver. In general the safety input is used for the power supply. As soon as voltage is present on the safety input a DMX signal is being generated with DMX channel 1 on 100%. The inputs 1-5 are translated to the DMX channels 2-6 (0% or 100%).

Even though DMX is considered to be an unsafe protocol (no checksums or other safety measures are implemented) the usage of this interface is rather safe, because the DMX signal is only generated if the interface is powered from the receiver’s output.

Safety channel Yes
Control channels 5 + Safety
Connectors on the inputs 4 mm banana plugs, fit in on every PFE Advanced receiver
Output XLR, 5 pins
Control time with terminal function 0.1s to 25.0s, Continuously On

Customer-specific solutions like e.g. different channel assignments are easily possible.

Interface with isolated switching outputs:

(Low Voltage Switching Interface)

This interface has two channels and it can be used whenever a device to be controlled requires a potential-free electrical contact. The outputs are optically isolated from the inputs.

The typical application for this interface is the control of film and photo cameras, high speed cameras and also smoke machines or all kinds of effect devices.

Normally it is used together with a receiver PFE Advanced 10 Outputs with Terminal function so that the duration how long the contacts will be closed can be programmed in the receiver’s menu. In addition several cues can be programmed to each output of the receiver.

Channels 2
Maximum switching current 1A
Maximum switching voltage 30V
Maximum isolation voltage 1,000V

 

Switching Interface for 230 Volts AC:

 

By connecting this interface to a receiver PFE Profi 3/10 Outputs or PFE Advanced 10 Outputs all kinds of devices that are powered with 230V mains supply can be controlled, i.e. switched on and off. This interface acts like a switch in the power cable.

Especially the usage of an Advanced receiver is meaningful together with the Terminal function, because this way several firing cues can be programmed to each output and in addition the duration how long the output should be active can be determined.

Typical applications are the control of wind machines, electromagnetic valves, electric motors and effect devices of all kinds.

Switching outputs 1
Connection ‘Schuko’ connector
Switching voltage 220VAC – 250VAC
Switching current 16A continuously
Switching power 3,680W
Control voltage 10VDC – 28VDC
Connection of the control cable 4 mm banana plugs,

suitable for all PFE Profi

and PFE Advanced receivers

PFE Profi 3 / 10 Outputs

Activation time:

Yes

0.5s and 2.6s

PFE Advanced 10 Outputs

Activation time:

Activation time with terminal function:

Yes

2.6s

0.1s to 25.0s, Continuously On

Customized solutions with different kinds of connectors are available upon request.

 

Interface with ‘0-10 Volt’ output:

 

This interface is build upon customer request. It is intended to control effect devices that have an input for 0-10 Volt signals. It is available as an optional accessory part for the receiver PFE Advanced 10 Outputs.

To activate an effect device several times with different firing cues and for different durations it is required that the receiver has been equipped with the optional terminal function.

 

Magic Effects Interface:

With this interface you can control the ‘Magic Effects Shooters’ from the

company ‘Magic Effects’ which is based in the Netherlands.

It is possible to use all our Galaxis receivers with 12V or 24V firing voltage.

Lines 5
Connection XLR 3 pins
External power supply to charge

the capacitors of the ‘Magic Effects

Shooters’

Yes, 8-24V DC
Autarkic operation with

PFE Profi 3/10 Ouptuts or

PFE Advanced 10 Outputs

(It is possible to charge the capacitors

of the ‘Magic Effects Shooters’ by

repetitively firing the same output.)

Yes
Autarkic operation with

PFE Advanced 10 Outputs and

the Terminal function of the receiver

(The capacitors in the ‘Magic

Effects Shooters’ are charged

by an output of the receiver which

is continuously.)

Yes
Status indicators display if the

charging level of the capacitors

in the ‘Magic Effects Shooters’

is sufficient.

Yes, one for each line
Mounting possibility for truss clamps and couplers with M10 screw thread Yes, twice
Mounting possibility for safety rope Yes, M10 screw threat
Possibility to control the

‘Magic Effects Interface’ LS2.030 etc.

Yes, XLR 7 pins
DMX Interface
Interface with isolated

switching outputs

Magic Effects Interface
Switching Interface for 230 Volts AC